The smallest range from AJ Power, the 3 Series, offers reliable power in an ultra compact solution. The 3 Series is powered by the world renowned Perkins and Deutz engines and offers optimum fuel consumption. A range of options are available to tailor your generating set to meet your needs, including optional canopy offering low noise level - perfect for urban locations.
SECTORS SERVED INCLUDE:
Telecommunications, Construction, Residential and Retail.
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
AJ10 | 50 Hz |
Single Phase
|
1500 | 6.6 | 7.3 | Perkins |
403D-11G ![]() |
AJ10 | 50 Hz |
Three Phase
|
1500 | 9.0 | 10.0 | Perkins |
403D-11G ![]() |
AJ14 | 50 Hz |
Single Phase
|
1500 | 9.5 | 10.6 | Perkins |
403D-15G ![]() |
AJ14 | 50 Hz |
Three Phase
|
1500 | 13.0 | 14.3 | Perkins |
403D-15G ![]() |
AJ22 | 50 Hz |
Single Phase
|
1500 | 15.1 | 16.6 | Perkins |
404D-22G ![]() |
AJ22 | 50 Hz |
Three Phase
|
1500 | 20.0 | 22.0 | Perkins |
404D-22G ![]() |
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
AJ10 | 60 Hz |
Single Phase
|
1800 | 8.3 | 9.2 | Perkins |
403D-11G ![]() |
AJ10 | 60 Hz |
Three Phase
|
1800 | 9.0 | 10.0 | Perkins |
403D-11G ![]() |
AJ14 | 60 Hz |
Single Phase
|
1800 | 11.7 | 13.0 | Perkins |
403D-15G ![]() |
AJ14 | 60 Hz |
Three Phase
|
1800 | 12.5 | 13.9 | Perkins |
403D-15G ![]() |
AJ22 | 60 Hz |
Three Phase
|
1800 | 18.0 | 20.0 | Perkins |
404D-22G ![]() |
AJ22 | 60 Hz |
Single Phase
|
1800 | 18.0 | 20.0 | Perkins |
404D-22G ![]() |
Model | AJ10 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 9.0 |
Standby kVA | 10.0 |
Engine | Perkins |
Model |
403D-11G ![]() |
Model | AJ22 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 18.0 |
Standby kVA | 20.0 |
Engine | Perkins |
Model |
404D-22G ![]() |
Model | AJ22 |
Frequency | 50 Hz |
Phase |
M Single Phase
|
R.P.M | 1500 |
P.R.P kVA | 15.1 |
Standby kVA | 16.6 |
Engine | Perkins |
Model |
404D-22G ![]() |
Model | AJ10 |
Frequency | 60 Hz |
Phase |
M Single Phase
|
R.P.M | 1800 |
P.R.P kVA | 8.3 |
Standby kVA | 9.2 |
Engine | Perkins |
Model |
403D-11G ![]() |
Model | AJ10 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 9.0 |
Standby kVA | 10.0 |
Engine | Perkins |
Model |
403D-11G ![]() |
Model | AJ14 |
Frequency | 60 Hz |
Phase |
M Single Phase
|
R.P.M | 1800 |
P.R.P kVA | 11.7 |
Standby kVA | 13.0 |
Engine | Perkins |
Model |
403D-15G ![]() |
Model | AJ14 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 13.0 |
Standby kVA | 14.3 |
Engine | Perkins |
Model |
403D-15G ![]() |
Model | AJ22 |
Frequency | 60 Hz |
Phase |
M Single Phase
|
R.P.M | 1800 |
P.R.P kVA | 18.0 |
Standby kVA | 20.0 |
Engine | Perkins |
Model |
404D-22G ![]() |
Model | AJ10 |
Frequency | 50 Hz |
Phase |
M Single Phase
|
R.P.M | 1500 |
P.R.P kVA | 6.6 |
Standby kVA | 7.3 |
Engine | Perkins |
Model |
403D-11G ![]() |
Model | AJ22 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 20.0 |
Standby kVA | 22.0 |
Engine | Perkins |
Model |
404D-22G ![]() |
To ensure world-class quality our engines are all manufactured in the United Kingdom, Europe, United States of America or Japan
All our alternators are UK sourced.
All the radiators that we use in our generating sets are European manufactured.
Water contamination in fuel is separated out with the fuel/water separator.
Heavy duty battery cables.
Full functional manual pack supplied with all generating sets.
Complete with power loom and Busbar connection point. (Not standard on 9 Series)
Removes contaminants in the air prior to entering the engine.
Voltage sensing via one phase.
Allows you to quickly stop the generating set in case of an emergency. Pressing the emergency stop button causes the generating set to shut down immediately.
Standard 30% antifreeze supplied with all generating sets. Upgade for colder ambients available as an option.
Minimises disturbances on the generators output from interference caused by non-linear loads. Also known as RFI.
Record of events - Events recorder InSight3250 (100 x FIFO), InSight6000 (300 x FIFO) - Not available with InSight3000.
kW, kWh and PF display - InSight3250/4000/6000 only
Overload - Standard on InSight4000 panel only. (Not available on InSight3000/3200/3250).
Basic automatic control panel with simple to use controls and numerical displays.
Improved protection against moisture ingress.
This is a self contained fuel tank in base frame of generating set.
Visual fuel level to help monitor fuel.
Fitted as standard on open generating sets.
Automatic control panel with electronic engine support as well as expansion and remote communication capabilities.
Automatic control panel with electronic engine support, expansion and remote communication capabilities, power factor/kW measurement, real time clock and event history.
Automatic mains failure control panel (can operate the generator and mains circuit breaker in the event of a mains failure). Features include power factor/kW measurement, real time clock and event history. Remote monitoring option available. Includes battery charger as standard.
Used to program the InSight3200/3250 operating parameters.
Used to program the InSight4000/ATSc (automatic transfer switch controller) operating parameters.
The LS-5 is a synchronising and load sharing controller to be used in conjunction with InSight6000. The LS-5 is designed to enable complex power management applications with multiple incoming mains and bus breakers. Supplied loose.
A modular panel mounted protection for generators operating in parallel to the mains supply. It incorporates a wide range of protection features and communication capabilities to safeguard both the power supplied and the generating sets. Works in accordance to G59 and G10.
A 16-channel display unit for remotely indicating the status of a generating set fitted with an InSight4000 & 6000 control panel. The annunciator communicates with the control panel and can be mounted up to 240 metres away from the generating set. 14 programmable outputs to suit your preferences.
Remotely control and monitor the generator with a separate remote panel identical to the one fitted on the genset.
Starts and stops the genset at a predefined time each week. (InSight3250/4000 only)
For InSight3200/3250. Provides the controller with 8 additional contacts which can be used as either inputs or outputs
An alarm activates on the control panel when it is time to service the machine. (Hours until service is adjustable, default: 400) Standard on InSight3200/3250/4000/6000.
If the voltage of the genset exceeds or drops below the nominal value, the machine alarms and shuts down. Standard on InSight3200/3250/4000/6000
If the frequency of the genset exceeds or drops below the nominal value, the machine alarms and shuts down. Standard on InSight3200/3250/4000/6000.
Protects the generator from importing power which will damage the machine. InSight3250/4000/6000 only
If the current on one of the phases exceeds the current on any of the other phases by a predefined percentage, the machine will produce a load imbalance alarm. InSight4000/6000 only
If the current exceeds a predefined limit for a certain period of time the machine alarms and shuts down. InSight4000/6000 only
The time it takes for the machine to shutdown is proportional to the magnitude of the overcurrent. i.e a large overcurrent will shutdown the machine faster than a smaller overcurrent. InSight4000/6000 only.
Programmable contacts for your required outputs.
Remote communications plug-in module. Ethernet interface/GSM/GPRS wireless remote monitoring with antenna.
Alarm annunciation, SMS / Email / SNMP, remote control & data logging. Internet access of controller possible over Ethernet LAN / GPRS. Includes DPC Kit, SMA Quadband Antenna.
To provide automatic control of your standby generating set in the event of a power outage. Available from 40A - 4000Amp.
Fully galvanised steel enclosure delivering durability and security for your generating set.
Accurately controls the engine speed. Recommended for synchronising. Standard on some models - Refer to factory.
Used to program or monitor the Woodward L series governor.
Helps the engine to start in cold weather.
Allows removal of lubricant during service or maintenance.
Assists in the removal of lubricant during service or maintenance.
Appropriate when the generating set is to be sited in a low ambient and /or high humidity environment. The heater maintains the air around the windings at a suitable temperature to prevent winding corrosion due to condensation.
Used to adjust setting on MeccAlte automatic voltage regulator.
Improves voltage stability of the alternator.
This is the ultimate solution to be used when the application or the environment is abusing the insulation of the generating set. Also includes an over-coating of all the rotating active components.
Coolant solution for ambients down to -36degC. 50% antifreeze.
Automatic high coolant temperature alarm at pre-set temperature level. Available with InSight4000/6000 only.
Secondary containment of fuel for leakage prevention.
Integral single skinned tank. (600, 1000, 1300 litres - canopied only)
Eye hook fitted to top centre of canopy. Provides means of lifting generating set and is useful during installation. Available with canopied models only. Please refer to factory for use on trailer mounted generating sets.
Required for mobile generator applications.
Automatic alarm for approaching low fuel level.
Visual fuel level % display on controller. Not available with InSight3000.
Gives fuel level indication at 4 set levels.
3 way dual valve with single lever operation. Complete with single lever operation. This should be used for remote fuel connection selection instead of basetank. Manual changeover between two fuel sources to the engine.
Essential kit for mounting an industrial silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provides additional exhaust noise reduction. Supplied loose. (Standard on all canopied sets)
Essential kit for mounting a residential silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provides flexible connection between engine and exhaust. Supplied loose.
This is an upgrade from the standard 3 pole circuit breaker. The neutral connection is broken as well as L1, L2 and L3. (3 phase only)
Provides the controller with an indication on the current circuit breaker position.
This is a ready to use socket supplied with the generating set. Equipment can be easily connected.
Provides protection for the main output breaker, complete with shunt trip. Detects unbalanced current between the phases of the machine and the neutral, resulting in the circuit breaker tripping open and the machine being shutdown
A lever is placed directly after the battery which is used to isolate the batteries from the machine
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure. 5A 220/240 Volt
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure and boost. 220/240 Volt
The generator is mounted on a road trailer to ease transporation between different locations. Trailer supplied is fixed height, 4 wheel, 50mm ball or eye. Available on canopied models only. Available up to and including AJ66.
Increased sound attenuation with container option. Bespoke containers available throughout the range.
Basic maintenance tools.
Adds additional protection to genset during shipping.
Additional guarding on exhaust manafolds. Certificate of compliance.
Certificate of compliance.
Additional operator manuals for workshop/service personnel.
Interested in this product? Get in touch