The 5 Series from AJ Power delivers exceptional performance, reliability, durability and low operating costs. All models within the range are available in both open and sound attenuated versions, with a full array of optional extras to match your requirements.
Powered by the class leading AGCO Power and Perkins engines the 5 Series offers excellent fuel consumption and is well equipped to deal with the even the most arduous conditions.
SECTORS SERVED INCLUDE:
Construction, residential, agriculture and commercial.
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
AJ33 | 60 Hz |
Single Phase
|
1800 | 22.5 | 25.0 | Perkins | 1103A-33G |
AJ33 | 60 Hz |
Three Phase
|
1800 | 33.8 | 37.5 | Perkins | 1103A-33G |
AJ50 | 60 Hz |
Single Phase
|
1800 | 35.0 | 38.0 | Perkins | 1003A-33TG1 |
AJ66 | 60 Hz |
Single Phase
|
1800 | 53.0 | 58.3 | Perkins | 1103A-33TG2 |
AJ50 | 60 Hz |
Three Phase
|
1800 | 56.3 | 62.5 | Perkins | 1103A-33TG2 |
AJ66 | 60 Hz |
Three Phase
|
1800 | 70.0 | 77.5 | Perkins | 1103A-33TG2 |
AJ88 | 60 Hz |
Three Phase
|
1800 | 95 | 105 | Perkins | 1104A-44TG2 |
AJ110 | 60 Hz |
Three Phase
|
1800 | 118.75 | 131.25 | Perkins | 1104C-44TAG2 |
AJ150 | 60 Hz |
Three Phase
|
1800 | 156.3 | 175.0 | Perkins | 1106A-44TG1 |
AJ165 | 60 Hz |
Three Phase
|
1800 | 168.8 | 187.5 | Perkins | 1106A-70TAG2 |
AJ200 | 60 Hz |
Three Phase
|
1800 | 200.0 | 218.8 | Perkins | 1106A-70TAG3 |
AJ250 | 60 Hz |
Three Phase
|
1800 | 230 | 250 | Perkins | 1206A-E70TTAG2 |
Model | AJ33 |
Frequency | 60 Hz |
Phase |
M Single Phase
|
R.P.M | 1800 |
P.R.P kVA | 22.5 |
Standby kVA | 25.0 |
Engine | Perkins |
Model | 1103A-33G |
Model | AJ50 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 56.3 |
Standby kVA | 62.5 |
Engine | Perkins |
Model | 1103A-33TG2 |
Model | AJ150 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 156.3 |
Standby kVA | 175.0 |
Engine | Perkins |
Model | 1106A-44TG1 |
Model | AJ275 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 250 |
Standby kVA | 275 |
Engine | Perkins |
Model | 1206A-E70TTAG3 |
Model | AJ50 |
Frequency | 50 Hz |
Phase |
M Single Phase
|
R.P.M | 1500 |
P.R.P kVA | 35.0 |
Standby kVA | 38.0 |
Engine | Perkins |
Model | 1103A-33TG1 |
Model | AJ66 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 45.0 |
Standby kVA | 50.0 |
Engine | Perkins |
Model | 1103A-33TG2 |
Model | AJ165 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 150.0 |
Standby kVA | 165.0 |
Engine | Perkins |
Model | 1106A-70TAG2 |
Model | AJ50 |
Frequency | 60 Hz |
Phase |
M Single Phase
|
R.P.M | 1800 |
P.R.P kVA | 35.0 |
Standby kVA | 38.0 |
Engine | Perkins |
Model | 1003A-33TG1 |
Model | AJ66 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 70.0 |
Standby kVA | 77.5 |
Engine | Perkins |
Model | 1103A-33TG2 |
Model | AJ165 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 168.8 |
Standby kVA | 187.5 |
Engine | Perkins |
Model | 1106A-70TAG2 |
Model | AJ66 |
Frequency | 50 Hz |
Phase |
M Single Phase
|
R.P.M | 1500 |
P.R.P kVA | 45.0 |
Standby kVA | 50.0 |
Engine | Perkins |
Model | 1103A-33TG2 |
Model | AJ88 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 80.0 |
Standby kVA | 88.0 |
Engine | Perkins |
Model | 1104A-44TG2 |
Model | AJ200 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 180.0 |
Standby kVA | 200.0 |
Engine | Perkins |
Model | 1106A-70TAG3 |
Model | AJ66 |
Frequency | 60 Hz |
Phase |
M Single Phase
|
R.P.M | 1800 |
P.R.P kVA | 53.0 |
Standby kVA | 58.3 |
Engine | Perkins |
Model | 1103A-33TG2 |
Model | AJ88 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 95 |
Standby kVA | 105 |
Engine | Perkins |
Model | 1104A-44TG2 |
Model | AJ200 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 200.0 |
Standby kVA | 218.8 |
Engine | Perkins |
Model | 1106A-70TAG3 |
Model | AJ33 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 30.0 |
Standby kVA | 33.0 |
Engine | Perkins |
Model | 1103A-33G |
Model | AJ110 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 100.0 |
Standby kVA | 110.0 |
Engine | Perkins |
Model | 1104C-44TAG2 |
Model | AJ220 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 200.0 |
Standby kVA | 220.0 |
Engine | Perkins |
Model | 1106A-70TAG4 |
Model | AJ33 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 33.8 |
Standby kVA | 37.5 |
Engine | Perkins |
Model | 1103A-33G |
Model | AJ110 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 118.75 |
Standby kVA | 131.25 |
Engine | Perkins |
Model | 1104C-44TAG2 |
Model | AJ250 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 230.0 |
Standby kVA | 250.0 |
Engine | Perkins |
Model | 1206A-E70TTAG2 |
Model | AJ33 |
Frequency | 50 Hz |
Phase |
M Single Phase
|
R.P.M | 1500 |
P.R.P kVA | 22.5 |
Standby kVA | 25.0 |
Engine | Perkins |
Model | 1103A-33G |
Model | AJ50 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 45.0 |
Standby kVA | 50.0 |
Engine | Perkins |
Model | 1103-33TG1 |
To ensure world-class quality our engines are all manufactured in the United Kingdom, Europe, United States of America or Japan.
All our alternators are UK sourced.
All the radiators that we use in our generating sets are European manufactured.
Water contamination in fuel is separated out with the fuel/water separator.
Heavy duty battery cables.
Full functional manual pack supplied with all generating sets.
Complete with power loom and Busbar connection point. (Not standard on 9 Series).
Removes contaminants in the air prior to entering the engine.
Voltage sensing via one phase.
Allows you to quickly stop the generating set in case of an emergency. Pressing the emergency stop button causes the generating set to shut down immediately.
Standard 30% antifreeze supplied with all generating sets. Upgade for colder ambients available as an option.
Minimises disturbances on the generators output from interference caused by non-linear loads. Also known as RFI.
Basic automatic control panel with simple to use controls and numerical displays.
This is a self contained fuel tank in base frame of generating set.
Industrial silencer standard on open sets.
Automatic control panel with electronic engine support as well as expansion and remote communication capabilities.
InSight4100 Digital Automatic Control Panel
Recommended for generating sets working in cold, arduous conditions.
InSight5200 Auto Synchronising With Other Generating Sets * (AR2 required with Newage alt only) (includes AR5 )
InSight6000S Auto Synchronising With Other Generating Sets ) * (AR2 required with Newage alt only) (includes AR5 )
The LS-5 is a synchronising and load sharing controller to be used in conjunction with InSight6000. The LS-5 is designed to enable complex power management applications with multiple incoming mains and bus breakers. Supplied loose.
Parallel Operation Loss of Mains Protection Relay Panel (G99) short term paralleling only.
Parallel Operation Loss of Mains Protection Relay Panel (G10)
Remotely control and monitor the generator with a separate remote panel identical to the one fitted on the genset.
remote panel supplied loose
Starts and stops the genset at a predefined time each week. (Insight3300/4100/5200/6000sonly)
Provides the controller with 8 additional contacts which can be used as either inputs or outputs. (Insight3300/4100/5200/only
Provides the controller with 8 additional inputs and 8 additional outputs.
Raise or lower the voltage from the controller/control panel
If the current on one of the phases exceeds the current on any of the other phases by a predefined percentage, the machine will produce a load imbalance alarm. InSight4000/6000 only.
If the current exceeds a predefined limit for a certain period of time the machine alarms and shuts down. InSight4000/6000 only.
The time it takes for the machine to shutdown is proportional to the magnitude of the overcurrent. i.e a large overcurrent will shutdown the machine faster than a smaller overcurrent. InSight4000/6000 only.
Programmable contacts for your required outputs.
Remote Communications Plug-In Module for InSight 3300/4100 - Ethernet interface
Remote Communications Plug-In Module for InSight 5200 - Ethernet interface
Remote Communications Plug-In Module for InSight 3300/4100 - GSM/GPRS Wireless Remote Monitoring with antenna
Remote Communications Plug-In Module for InSight 5200 - GSM/GPRS Wireless Remote Monitoring with antenna
Remote Communications Plug-In Module for InSight 3300/4100 to support RS232 and RS485 modbus RTU interfaces
Remote Communication Solution for InSight6000s. Alarm annunciation, SMS / Email / SNMP, 'remote control & data logging. Internet access of controller possible over Ethernet LAN / GPRS. Includes DPC Kit, SMA Quadband Antenna.
To provide automatic control of your standby generating set in the event of a power outage. Available from 40A - 4000Amp
Fully galvanised steel enclosure delivering durability and security for your generating set.
Accurately controls the engine speed. Recommended for synchronising. Standard on some models - Refer to factory.
Used to program or monitor the Woodward L series governor
Helps the engine to start in cold weather.
Allows removal of lubricant during service or maintenance.
Assists in the removal of lubricant during service or maintenance.
Appropriate when the generating set is to be sited in a low ambient and/or high humidity environment, the heater maintains the air around the windings at a suitable temperature to prevent winding corrosion due to condensation.
High overload ability for motor starting.
Used to adjust setting on MeccAlte automatic voltage regulator.
More accurate voltage regulation with unbalanced loads.
This is the ultimate solution to be used when the application or the environment is abusing the insulation of the generating set. Also includes an overcoating of all the rotating active components.
Improved protection against moisture ingress.
Change standard alternator to Newage Stamford alternator.
Open sets only. Allows ease of fitting of transition during room installation
Open sets only. To prevent water and dust ingress in conjunction with sound attenuator. (room installations)
Coolant solution for ambients down to -36degC. 50% antifreeze.
Automatic high coolant temperature alarm at pre-set temperature level. Available with InSight4000/6000 only.
Automatic low coolant level alarm at pre-set low level measurement. Not available with InSight3000.
Secondary containment of fuel for leakage prevention.
Automatic alarm upon detection of fluid in bund.
Extended tank. Available for canopied models only.
Eye hook fitted to top centre of canopy. Provides means of lifting generating set and is useful during installation. Available with canopied models only. Please refer to factory for use on trailer mounted generating sets.
Required for mobile generator applications.
Visual fuel level to help monitor fuel.
In the event of a fire, the fuel supply is cut off from the machine and a signal is sent to the controller to stop the machine.
Automatic alarm for approaching low fuel level.
Visual fuel level % display on controller. Not available with InSight3000.
Gives fuel level indication at 4 set levels
3 way dual valve complete with single lever operation. This should be used for remote fuel connection selection instead of basetank. Manual change over between two fuel sources to the engine
Manually operated fuel transfer pump, comes complete with hose.
Automatic fuel transfer pump, activated at a set generator fuel tank level. The system includes a level switch, a motorised valve, and pump. Also includes upgrade to metal fuel tank.
Essential kit for mounting an industrial silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provides additional exhaust noise reduction. Supplied loose. (Standard on all canopied sets)
Essential kit for mounting a residential silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provides flexible connection between engine and exhaust. Supplied loose.
This is an upgrade from the standard 3 pole circuit breaker. The neutral connection is broken as well as L1, L2 and L3. (3 phase only)
Provides the controller with an indication on the current circuit breaker position.
Enables the automatic operation of the circuit breaker throught external signals. i.e. open and close signals from the genset controller.
Provides protection for the main output breaker, complete with shunt trip. Detects unbalanced current between the phases of the machine and the neutral, resulting in the circuit breaker tripping open and the machine being shutdown.
A lever is placed directly after the battery which is used to isolate the batteries from the machine.
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure. 5A 220/240 Volt.
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure and boost. 220/240 Volt.
Basic maintenance tools.
Adds additional protection to genset during shipping.
Additional guarding on exhaust manafolds. Certificate of compliance. Europe Only
Certificate of compliance Europe Only
Additional operator manuals for workshop/service personnel.
Certificate of compliance UK Only
Certificate of compliance UK Only