From whatever angle you look at it, there is no denying the high standards and attention to detail that have been applied to the design of the entire 7 Series range.
Ready to meet the demands of your industry, the 7 Series boasts an array of standard features plus a complete range of additional options.
The 7 Series range is powered by Scania and Perkins engines. These engines offer high performance cooling systems, high uptime, low operational costs and long service internals - delivering power you can depend on.
SECTORS SERVED INCLUDE:
Industrial, construction, mining, commercial, events and utilities.
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
AJ280 | 50 Hz |
Three Phase
|
1500 | 250 | 280 | Scania | DC9 72A |
AJ310 | 50 Hz |
Three Phase
|
1500 | 280 | 310 | Scania | DC9 72A 02-12 |
AJ330 | 50 Hz |
Three Phase
|
1500 | 300 | 330 | Scania | DC9 72A |
AJ360 | 50 Hz |
Three Phase
|
1500 | 330 | 360 | Scania | DC9 72A 02-14 |
AJ375 | 50 Hz |
Three Phase
|
1500 | 350 | 375 | Scania | DC13 72A |
AJ400 | 50 Hz |
Three Phase
|
1500 | 370 | 400 | Scania | DC13 72A |
AJ440 | 50 Hz |
Three Phase
|
1500 | 400 | 440 | Scania | DC13 72A |
AJ460 | 50 Hz |
Three Phase
|
1500 | 410 | 460 | Scania | DC13 72A |
AJ500 | 50 Hz |
Three Phase
|
1500 | 450 | 500 | Scania | DC13 72A |
AJ550 | 50 Hz |
Three Phase
|
1500 | 500 | 550 | Scania | DC13 72A |
AJ615 | 50 Hz |
Three Phase
|
1500 | 560 | 615 | Scania | DC16 093A-52 |
AJ670 | 50 Hz |
Three Phase
|
1500 | 610 | 670 | Scania | DC16 093A 02-53 |
AJ710 | 50 Hz |
Three Phase
|
1500 | 650 | 710 | Scania | DC16 093A 02-54 |
AJ770 | 50 Hz |
Three Phase
|
1500 | 700 | 770 | Scania | DC16 78A |
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
AJ280 | 60 Hz |
Three Phase
|
1800 | 281.25 | 312.5 | Scania | DC9 072A |
AJ310 | 60 Hz |
Three Phase
|
1800 | 306.25 | 343.75 | Scania | DC9 072A 02-12 |
AJ330 | 60 Hz |
Three Phase
|
1800 | 325 | 368.75 | Scania | DC9 072A |
AJ360 | 60 Hz |
Three Phase
|
1800 | 362.5 | 412.5 | Scania | DC9 072A |
AJ375 | 60 Hz |
Three Phase
|
1800 | 387.5 | 437.5 | Scania | DC13 072A |
AJ400 | 60 Hz |
Three Phase
|
1800 | 412.5 | 462.5 | Scania | DC13 072A |
AJ440 | 60 Hz |
Three Phase
|
1800 | 431.25 | 500 | Scania | DC13 072A |
AJ460 | 60 Hz |
Three Phase
|
1800 | 450 | 512.35 | Scania | DC13. 072A |
AJ500 | 60 Hz |
Three Phase
|
1800 | 500 | 556.25 | Scania | DC13 072A |
AJ615 | 60 Hz |
Three Phase
|
1800 | 550 | 606.25 | Scania | DC16 093 02-52 |
AJ670 | 60 Hz |
Three Phase
|
1800 | 608.75 | 671.25 | Scania | DC16 093A 02-52 |
AJ710 | 60 Hz |
Three Phase
|
1800 | 661.25 | 730 | Scania | DC16 093A 02-54 |
AJ770 | 60 Hz |
Three Phase
|
1800 | 700 | 770 | Scania | DC16 78A |
Model | AJ330 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 300 |
Standby kVA | 330 |
Engine | Scania |
Model | DC9 72A |
Model | AJ615 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 560 |
Standby kVA | 615 |
Engine | Scania |
Model | DC16 093A-52 |
Model | AJ375 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 387.5 |
Standby kVA | 437.5 |
Engine | Scania |
Model | DC13 072A |
Model | AJ360 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 330 |
Standby kVA | 360 |
Engine | Scania |
Model | DC9 72A 02-14 |
Model | AJ670 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 610 |
Standby kVA | 670 |
Engine | Scania |
Model | DC16 093A 02-53 |
Model | AJ400 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 412.5 |
Standby kVA | 462.5 |
Engine | Scania |
Model | DC13 072A |
Model | AJ375 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 350 |
Standby kVA | 375 |
Engine | Scania |
Model | DC13 72A |
Model | AJ710 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 650 |
Standby kVA | 710 |
Engine | Scania |
Model | DC16 093A 02-54 |
Model | AJ440 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 431.25 |
Standby kVA | 500 |
Engine | Scania |
Model | DC13 072A |
Model | AJ710 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 661.25 |
Standby kVA | 730 |
Engine | Scania |
Model | DC16 093A 02-54 |
Model | AJ400 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 370 |
Standby kVA | 400 |
Engine | Scania |
Model | DC13 72A |
Model | AJ770 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 700 |
Standby kVA | 770 |
Engine | Scania |
Model | DC16 78A |
Model | AJ460 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 450 |
Standby kVA | 512.35 |
Engine | Scania |
Model | DC13. 072A |
Model | AJ670 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 608.75 |
Standby kVA | 671.25 |
Engine | Scania |
Model | DC16 093A 02-52 |
Model | AJ440 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 400 |
Standby kVA | 440 |
Engine | Scania |
Model | DC13 72A |
Model | AJ280 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 281.25 |
Standby kVA | 312.5 |
Engine | Scania |
Model | DC9 072A |
Model | AJ500 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 500 |
Standby kVA | 556.25 |
Engine | Scania |
Model | DC13 072A |
Model | AJ460 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 410 |
Standby kVA | 460 |
Engine | Scania |
Model | DC13 72A |
Model | AJ310 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 306.25 |
Standby kVA | 343.75 |
Engine | Scania |
Model | DC9 072A 02-12 |
Model | AJ615 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 550 |
Standby kVA | 606.25 |
Engine | Scania |
Model | DC16 093 02-52 |
Model | AJ280 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 250 |
Standby kVA | 280 |
Engine | Scania |
Model | DC9 72A |
Model | AJ500 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 450 |
Standby kVA | 500 |
Engine | Scania |
Model | DC13 72A |
Model | AJ330 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 325 |
Standby kVA | 368.75 |
Engine | Scania |
Model | DC9 072A |
Model | AJ770 |
Frequency | 60 Hz |
Phase |
T Three Phase
|
R.P.M | 1800 |
P.R.P kVA | 700 |
Standby kVA | 770 |
Engine | Scania |
Model | DC16 78A |
Model | AJ310 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 280 |
Standby kVA | 310 |
Engine | Scania |
Model | DC9 72A 02-12 |
To ensure world-class quality our engines are all manufactured in the United Kingdom, Europe, United States of America or Japan.
All our alternators are UK sourced.
All the radiators that we use in our generating sets are European manufactured.
Water contamination in fuel is separated out with the fuel/water separator
Heavy duty battery cables.
Full functional manual pack supplied with all generating sets.
Complete with power loom and Busbar connection point.
Removes contaminants in the air prior to entering the engine.
Voltage sensing via one phase.
Allows you to quickly stop the generating set in case of an emergency. Pressing the emeergency stop button causes the generating set to shut down immediately.
Standard 30% antifreeze supplied with all generating sets. Upgade for colder ambients available as an option.
Minimises disturbances on the generators output from interference caused by non-linear loads. Also known as RFI.
Industrial Silencer is standard on all open sets.
Automatic control panel with electronic engine support as well as expansion and remote communication capabilities
Allows easy drainage of coolant during service or maintenance. Standard on canopied version only.
Allows removal of lubricant during service or maintenance.
This is a self contained fuel tank in base frame of generating set.
InSight3300 Digital Automatic Control Panel
InSight4100 Digital Automatic Control Pane
Recommended for generating sets working in cold, arduous conditions.
InSight5200 Auto Synchronising
InSight6000S Auto Synchronising With Other Generating Sets (Woodward Easygen 3200 XT) * (AR2 required with Newage alt only) (includes AR5 )
The LS-5 is a synchronising and load sharing controller to be used in conjunction with InSight6000. The LS-5 is designed to enable complex power management applications with multiple incoming mains and bus breakers. Supplied loose.
Parallel Operation Loss of Mains Protection Relay Panel (G99) short term paralleling only.
Parallel Operation Loss of Mains Protection Relay Panel (G10)
Remotely control and monitor the generator with a separate remote panel identical to the one fitted on the genset.
Starts and stops the genset at a predefined time each week. (Not available on InSight3200)
Provides the controller with 8 additional contacts which can be used as either inputs or outputs.
Provides the controller with 8 additional inputs and 8 additional outputs.
Raise or lower the voltage from the controller/control panel.
Programmable contacts for your required outputs.
Remote Communications Plug-In Module for InSight 3300/4100 - Ethernet interface
Remote Communications Plug-In Module for InSight 5200 - Ethernet interface
Remote Communications Plug-In Module for InSight 3300/4100 - GSM/GPRS Wireless Remote Monitoring with antenna
Remote Communications Plug-In Module for InSight 5200 - GSM/GPRS Wireless Remote Monitoring with antenna
Remote Communications Plug-In Module for InSight3300/4100 to support RS232 and RS485 modbus RTU interfaces
Remote Communication Solution for InSight6000s. Alarm annunciation, SMS / Email / SNMP, 'remote control & data logging. Internet access of controller possible over Ethernet LAN / GPRS. Includes DPC Kit, SMA Quadband Antenna.
To provide automatic control of your standby generating set in the event of a power outage. Available from 40A - 4000Amp.
Fully galvanised steel enclosure delivering durability and security for your generating set.
Accurately controls the engine speed. Recommended for synchronising. Standard on some models - Refer to factory.
Used to program or monitor the Woodward L series governor
Helps the engine to start in cold weather.
Assists in the removal of lubricant during service or maintenance.
Appropriate when the generating set is to be sited in a low ambient and/or high humidity environment, the heater maintains the air around the windings at a suitable temperature to prevent winding corrosion due to condensation.
High overload ability for motor starting.
Used to adjust setting on MeccAlte automatic voltage regulator.
More accurate voltage regulation with unbalanced loads.
This is the ultimate solution to be used when the application or the environment is abusing the insulation of the generating set. Also includes an overcoating of all the rotating active components.
Improved protection against moisture ingress.
Change standard alternator to Newage Stamford alternator.
Open sets only. Allows ease of fitting of transition during room installation.
Open sets only. To prevent water and dust ingress in conjunction with sound attenuator. (Room installations.)
Coolant solution for ambients down to -36degC. 50% antifreeze.
Automatic low coolant temperature alarm at pre-set temperature level. Not available with InSight3000
Automatic high coolant temperature alarm at pre-set temperature level. Available with InSight4000/6000 only
Automatic low coolant level alarm at pre-set low level measurement. Not available with InSight3000.
Secondary containment of fuel for leakage prevention.
Automatic alarm upon detection of fluid in bund.
Eye hook fitted to top centre of canopy. Provides means of lifting generating set and is useful during installation. Available with canopied models only. Please refer to factory for use on trailer mounted generating sets.
Required for mobile generator applications.
Visual fuel level to help monitor fuel.
In the event of a fire, the fuel supply is cut off from the machine and a signal is sent to the controller to stop the machine.
Automatic alarm for approaching low fuel level.
Automatic shutdown upon low fuel level detection.
Visual fuel level % display on controller. Not available with InSight3000.
Gives fuel level indication at 4 set levels.
Complete with single lever operation. This should be used for remote fuel connection selection instead of basetank. Manual change over between two fuel sources to the engine.
Manually operated fuel transfer pump, comes complete with hose.
Automatic fuel transfer pump, activated at a set generator fuel tank level. The system includes a level switch, a motorised valve, and pump. Also includes upgrade to metal fuel tank.
Essential kit for mounting an industrial silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provides additional exhaust noise reduction. Supplied loose. (Standard on all canopied sets)
Essential kit for mounting a residential silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provide flexible connection between engine and exhaust. Supplied loose. Required for open sets only.
This is an upgrade from the standard 3 pole circuit breaker. The neutral connection is broken as well as L1, L2 and L3. (3 phase only)
Provides the controller with an indication on the current circuit breaker position.
Enables the automatic operation of the circuit breaker throught external signals. i.e. open and close signals from the genset controller.
Provides protection for the main output breaker, complete with shunt trip. Detects unbalanced current between the phases of the machine and the neutral, resulting in the circuit breaker tripping open and the machine being shutdown
Earth Leakages for Main Output circuit breaker only available on LSIG ABB breaker
A lever is placed directly after the battery which is used to isolate the batteries from the machine.
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure. 5A 220/240 Volt.
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure and boost. 220/240 Volt.
Increased sound attenuation with container option. Bespoke containers available throughout the range.
Basic maintenance tools.
Additional guarding on exhaust manafolds. Certificate of compliance. Europe Only
Certificate of compliance Europe Only
Certificate of compliance UK ONLY
Certificate of compliance UK ONLY
Additional operator manuals for workshop/service personnel.
Interested in this product? Get in touch