The 9 Series is the largest power range from AJ Power. Whether it be low or high voltage (3.3-13.8kV), our engineer’s can come up with a solution.
The 9 Series comes in open set versions or can be supplied with bespoke sound attenuated weatherproof containers and enclosures.
A wide range of technical additional options are available on these generating sets to ensure the ultimate solution. Offering a choice of Perkins, Cummins or Mitsubishi engines, the 9 Series can meet the demands of all you critical power requirements.
SECTORS SERVED INCLUDE:
Data Centres, Healthcare, Commercial, Industrial and Banking.
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
AJ1650 | 50 Hz |
Three Phase
|
1500 | 1500 | 1650 | Mitsubishi | S12 R F1 PTAW2 |
AJ1710 | 50 Hz |
Three Phase
|
1500 | 1540 | 1710 | Mitsubishi | S12R F1 PTAW2 |
AJ2275 | 50 Hz |
Three Phase
|
1500 | 2085 | 2275 | Mitsubishi | S16R F1 PTAW2 |
AJ2530 | 50 Hz |
Three Phase
|
1500 | 2300 | 2530 | Mitsubishi | S16R2 F1PTAW |
Model | Frequency | Phase | R.P.M | Prime-kVA | Standby kVA | Engine | Model |
Model | AJ1650 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 1500 |
Standby kVA | 1650 |
Engine | Mitsubishi |
Model | S12 R F1 PTAW2 |
Model | AJ1710 |
Frequency | 50 Hz |
Phase |
T Three Phase
|
R.P.M | 1500 |
P.R.P kVA | 1540 |
Standby kVA | 1710 |
Engine | Mitsubishi |
Model | S12R F1 PTAW2 |
To ensure world-class quality our engines are all manufactured in the United Kingdom, Europe, United States of America or Japan.
All our alternators are UK sourced.
All the radiators that we use in our generating sets are European manufactured.
Water contamination in fuel is separated out with the fuel/water separator.
Heavy duty battery cables.
Full functional manual pack supplied with all generating sets.
Removes contaminants in the air prior to entering the engine.
Voltage sensing via one phase.
Allows you to quickly stop the generating set in case of an emergency. Pressing the emergency stop button causes the generating set to shut down immediately.
Standard 30% antifreeze supplied with all generating sets. Upgade for colder ambients available as an option.
Minimises disturbances on the generators output from interference caused by non-linear loads. Also known as RFI.
Automatic control panel with electronic engine support as well as expansion and remote communication capabilities.
Allows easy drainage of coolant during service or maintenance. STD on canopy.
Allows removal of lubricant during service or maintenance.
Accurately controls the engine speed. Recommended for synchronising.
InSight4100 Digital Automatic Control Panel
Recommended for generating sets working in cold, arduous conditions.
InSight5200 Auto Synchronising With Other Generating Sets ( * (AR2 required with Newage alt only) (includes AR5 )
InSight6000S/6400S Auto Synchronising With Other Generating Sets * (AR2 required with Newage alt only) (includes AR5 )
The LS-5 is a synchronising and load sharing controller to be used in conjunction with InSight6000. The LS-5 is designed to enable complex power management applications with multiple incoming mains and bus breakers. Supplied loose.
LS5 panel Loose - controls two breakers and can be applied where load bus is served by a utility breaker and a group breaker – To be used with PN64S option only
Parallel Operation Loss of Mains Protection Relay Panel (G99) short term paralleling only. .
Parallel Operation Loss of Mains Protection Relay Panel (G10)
Remotely control and monitor the generator with a separate remote panel identical to the one fitted on the genset.
Starts and stops the generating set at a predefined time each week. Not available on InSight3200.
Provides the controller with 8 additional contacts which can be used as either inputs or outputs.
Provides the controller with 8 additional inputs and 8 additional outputs.
Raise or lower the voltage from the controller/control panel.
Programmable contacts for your required outputs.
Remote Communications Plug-In Module for InSight 3300/4100 - Ethernet interface
Remote Communications Plug-In Module for InSight 5200 - Ethernet interface
Remote Communications Plug-In Module for InSight 3300/4100 - GSM/GPRS Wireless Remote Monitoring with antenna
Remote Communications Plug-In Module for InSight 5200 - GSM/GPRS Wireless Remote Monitoring with antenna
Remote Communications Plug-In Module for InSight3300/4100 to support RS232 and RS485 modbus RTU interfaces
Remote Communication Solution for InSight6000s. Alarm annunciation, SMS / Email / SNMP, 'remote control & data logging. Internet access of controller possible over Ethernet LAN / GPRS. Includes DPC Kit, SMA Quadband Antenna.
To provide automatic control of your standby generating set in the event of a power outage. Available from 40A - 4000Amp.
Helps the engine to start in cold weather.
Assists in the removal of lubricant during service or maintenance.
The genset will shutdown once the oil temperature exceeds a preset limit.
Appropriate when the generating set is to be sited in a low ambient and/or high humidity environment, the heater maintains the air around the windings at a suitable temperature to prevent winding corrosion due to condensation.
High overload alitity for motor starting
Used to adjust setting on Meccalte automatic voltage regualtor
More accurate voltage regulation with unbalanced loads
This is the ultimate solution to be used when the application or the environment is abusing the insulation of the generating set. Also includes an overcoating of all the rotating active components.
Alternator factory fitted - additional lead time. Refer to factory for further information.
RTD's. Alternator factory fitted - additional lead time. Refer to factory for further information.
Change standard alternator to Newage Stamford alternator.
Open sets only. Allows ease of fitting of transition during room installations.
Open sets only. To prevent water and dust ingress in conjunction with sound attenuator (room installations).
Coolant solution for ambients down to -36degC. 50% antifreeze.
Automatic low coolant temperature alarm at pre-set temperature level. Not available with InSight3000.
Automatic high coolant temperature alarm at pre-set temperature level. Available with InSight4000/6000 only.
Automatic low coolant level alarm at pre-set low level measurement. Not available with InSight3000.
Essential kit for mounting an industrial silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
Provides additional exhaust noise reduction. Supplied loose. (Standard on all canopied sets)
Essential kit for mounting a residential silencer during installation. This kit is supplied loose and includes 2 x cuffed elbows, 2 x support brackets, 6 x clamps and 1 x rain cap.
MCCB up to 1600Amp. 2000Amp and above are ACB.
This is an upgrade from the standard 3 pole circuit breaker. The neutral connection is broken as well as L1, L2 and L3. (3 phase only)
Provides the controller with an indication on the current circuit breaker position.
Enables the automatic operation of the circuit breaker throught external signals. i.e. open and close signals from the genset controller.
Earth Leakages for Main Output circuit breaker only available on LSIG ABB breaker (Circuit breaker must be ordered with genset)
A lever is placed directly after the battery which is used to isolate the batteries from the machine.
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure. 5A 220/240 Volt.
Keeps the genset starting batteries full of charge when the machine is not running. Includes BC failure and boost. 220/240 Volt.
Increased sound attenuation with container option. Bespoke containers available throughout the range.
Basic maintenance tools.
Additional guarding on exhaust manafolds. Certificate of compliance. EU ONLY
Certificate of compliance. EU ONLY
Certificate of compliance. UK ONLY
Certificate of compliance. UK ONLY
Additional operator manuals for workshop/service personnel.
Interested in this product? Get in touch
Make an enquiry